HeaderPane
Main
Hide
Share Link
Print

Error Messages

The method used to handle errors depends on the development language/tool used. Some provide special mechanisms to retrieve error message codes and message text. In .NET, a failing property or method raises a System.Runtime.InteropServices.COMException whose Message is the error text shown below. Please see your development tool's documentation for specific information on error handling.

C and C++ users can use the #include file \Program Files (x86)\Softelvdm\SftDate OCX 2.0\Include\SftDateOCXErrors.h. It offers predefined preprocessor symbols for the errors generated by SftDate/OCX (i.e., the errors shown below named SFTDATE_E_xxx and SFTDATAOBJECT_E_xxx). The standard errors (CTL_E_xxx) are defined in the Windows SDK header file olectl.h.

ErrorDescription
7 (CTL_E_OUTOFMEMORY)An object could not be allocated, for example "Can't allocate SftDateSpecialDate object.".
380 (CTL_E_INVALIDPROPERTYVALUE)A property was set to an invalid value, or a method argument is invalid. The text names the property, for example "The Recurrence value is invalid.", or describes the reason:
"The date is outside the range defined by MinDate and MaxDate, or the control does not allow an empty value." - Value, RangeStart or RangeEnd was set to a date outside the limits (MinDate, MaxDate), or to Null for a date field control that allows neither an empty value (AllowEmpty) nor a cleared check box (ShowCheckBox).
"The range is outside the range defined by MinDate and MaxDate, or longer than Calendar.MaxRangeDays." - SetRange was called with an invalid range (see MaxRangeDays).
"The date is outside the range defined by MinDate and MaxDate." - FocusedDate of a month calendar control.
"The view is not one of Calendar.AllowedViews." - View of a month calendar control (see AllowedViews).
"The text is not a valid date or time for this field." - Text of a date field control.
"The locale is unknown, or does not offer the calendar defined by CalendarType." - Culture.
"The locale defined by Culture does not offer this calendar." - CalendarType (see GetOptionalCalendars).
"The date is outside the supported range." - the date of a special date (Add, Insert, Date) is not within the years 100 to 9999.
387 (CTL_E_SETNOTPERMITTED)The property cannot be set at this time, for example the _FlatProperties property at run time.
394 (CTL_E_GETNOTSUPPORTED)The property cannot be retrieved at this time, for example the _FlatProperties and License properties at run time.
481 (CTL_E_INVALIDPICTURE)The picture object is invalid, or is not of a type the property accepts. The MouseIcon property only accepts icons.
1004 (SFTDATE_E_INVALIDINDEX)"The special date index is invalid." - The Index argument of a SftDateSpecialDates method or property (Item, Insert, Remove) is out of bounds. The index is zero-based, which means the valid range of index values is 0 to Count - 1 (0 to Count for Insert).
1005 (SFTDATE_E_NOTNOW)"A range can only be set when SelectionMode is selectionSftDateRange." - SetRange was called for a control that selects single dates (SelectionMode).
1100 (SFTDATE_E_OBJECTINVALID)"The SftDateCalendar object refers to a destroyed control." or "The SftDateSpecialDates object refers to a destroyed control." - A SftDateCalendar or SftDateSpecialDates object is used (or an interface pointer references an object) after the control it belongs to has been destroyed. This can occur if a reference to the object is saved, for example in a variable of a form, and used after the form and its controls have been closed.
2000 (SFTDATAOBJECT_E_INVALIDUSE)A DataObject is used in an inconsistent manner. A drop target cannot update the DataObject and a drag source cannot retrieve data from the DataObject.
2001 (SFTDATAOBJECT_E_UNSUPPORTEDFORMAT)The data format or storage medium to be added to the DataObject or about to be retrieved is not supported by the product.
2002 (SFTDATAOBJECT_E_ARGREQ)A required argument is missing. Please see the documentation of the failing property or method.
2003 (SFTDATAOBJECT_E_TYPEBAD)The data argument has a type which is inconsistent with the specified data format.
2004 (SFTDATAOBJECT_E_NOSUCHFORMAT)The Format requested using the DataObject.GetData method is not available. It has not been added to the DataObject by the drag source.
2005 (SFTDATAOBJECT_E_NODATA)No data has been provided to the DataObject by the drag source, even though the drag source indicated that the specified Format will be available.
2006 (SFTDATAOBJECT_E_OBJECTINVALID)A DataObject object is used (or an interface pointer references an object) which is no longer valid. This can occur if a reference to an object is saved, but the object has been removed.
2010 (SFTDATAOBJECTFILES_E_INDEXINVALID)An invalid item index was specified (usually the ItemIndex argument). The item index is one-based, which means the valid range of index values is 1..DataObjectFiles.Count. Please see the documentation of the failing property or method.
2011 (SFTDATAOBJECTFILES_E_OBJECTINVALID)A DataObjectFiles object is used (or an interface pointer references an object) which is no longer valid. This can occur if a reference to an object is saved, but the object has been removed.
2200 (SFTPICTURE_E_OBJECTINVALID)A SftPictureObject object is used (or an interface pointer references an object) which is no longer valid. This can occur if a reference to an object is saved, but the object it belongs to has been removed.

Using the property pages at run time fails with the error "Property pages are not supported at runtime." (E_UNEXPECTED); the property pages are only available at design time.


Last Updated 11/29/2026 - (email)
© 2026 Softel vdm, Inc.