The conversion is not automatic, but takes just a few minutes for a project.
Only a minimal conversion is required when upgrading from SftTabs/OCX 6.5 (or an older version) to SftTabs/OCX 7.0. SftTabs/OCX 7.0 is virtually 100% source compatible with older releases of SftTabs/OCX and SftTabs/ATL. Your application(s) must be recompiled to use SftTabs/OCX 7.0.
SftTabs/OCX 7.0 and older versions can coexist on the same system (both can be installed at the same time). They cannot be used in the same application. In order to convert an application, both the older version and SftTabs/OCX 7.0 must be installed.
Make sure to back up your current projects, before converting your projects. After converting, once the control saves updated property settings, you will not be able to return to SftTabs/OCX 6.5.
After installing SftTabs/OCX 7.0, all your projects will continue to use SftTabs/OCX 6.5 until you make the following change in each project's VBP (Visual Basic Project) file and in its forms. Make sure to close the project in Visual Basic, then edit the VBP file using a text editor and make the following change:
Existing Project:
Type=Exe Form=Form1.frm Reference=*\G{{00020430-0000-0000-C000-000000000046}}#2.0#0#C:\Windows\SysWOW64\stdole2.tlb#OLE Automation Object={{919B661B-D0B2-4961-B128-D7C32DF3B10C}}#6.5#0; SftTabs_IX86_U_65.ocx IconForm="Form1" Startup="Form1" ExeName32="Features.exe" Command32="" Name="Project1"
The line describing SftTabs/OCX 6.5 (using a bold font) should be replaced with the following line:
Object={{9B787CF3-B2CF-417B-844B-90040FFCB281}}#7.0#0; SftTabs_IX86_U_70.ocxYou can copy this line directly from this page. The line must be copied as-is, without any modifications.
Each form (FRM file) that contains a tab control also names the control. Edit each form using a text editor and make the following changes:
Once the files have been saved, you can open the project in Visual Basic. As you open each form containing a tab control, it is converted to SftTabs/OCX 7.0. Each form must be opened and saved to complete the conversion.
The controls will save updated property settings, so you will not be able to return to SftTabs/OCX 6.5.
When upgrading from a version older than 6.5, the Object line names that version (for example SftTabs_IX86_U_60.ocx) and is replaced the same way.
When upgrading from SftTabs/OCX 6.5, no changes must be made. The new features of version 7.0 (dark mode, high contrast, image and pixel scaling) are off unless the application enables them.
When upgrading from SftTabs/OCX 6.0 or earlier, the following applies:
When upgrading from SftTabs/ATL 4.0 or earlier, the following applies:
An application converted to SftTabs/OCX 7.0 uses the control SftTabs_IX86_U_70.ocx. The files of the older version are no longer needed by the application. Please see "Distributing SftTabs/OCX" for more information.